Continuous Device Functionality Monitoring

System

Continuous functionality monitoring is a proposed countermeasure for quantum communication systems, aimed at preserving the integrity and effectiveness of security components like optical isolators, monitors, and watchdog detectors.

Literature 1
[Makarov2016] V. Makarov, J.-P. Bourgoin, P. Chaiwongkhot, M. Gagné, T. Jennewein, S. Kaiser, R. Kashyap, M. Legré, C. Minshull, and S. Sajeed. "Creation of backdoors in quantum communications via laser damage" In: Phys. Rev. A 94, 030302(R). (2016) 10.1103/PhysRevA.94.030302.
QID: CM-0012
UUID: 478b68d7-522c-4b15-a71f-30e7f93d8547
Tier: T0
Type: Monitoring
Domain(s):
  • Quantum Communication
Tactic: Detect
Created: 2024-03-02
Updated: 2026-11-12
Countermeasure properties

Target party: Receiver, Transmitter
Quantum channel: Fibre optic, Free space
Security layers: L4 — System Control & Orchestration
Technique → Countermeasures 6
Description Technique

Continuous device functionality monitoring is the general in-operation form of the control this family most directly defeats, and it applies at both parties rather than only at the receiver, which is what distinguishes it from the detector-only monitoring edge on this same entity. The gap it addresses is stated plainly: no deployed system has a mechanism to check all possible deviations in device characteristics from the modeled values [Makarov2016]. The honest form of the control is that it is advisable to monitor the characteristics of the system directly during QKD, or at least to bound them during QKD with sufficiently high probability [Bugge2014].

A-0058 Laser Damage Attack on Quantum Communication Systems

This control is on the row because the primary defence can be silently removed. Zhang2022 states that the external isolator can be damaged by an ultrastrong light attack and its degree of isolation effectively reduced, and therefore that it must be paired with an opposite-intensity monitoring device to detect whether strong optical injection damages the external isolator. Pang2020 points the same way, noting that the attenuation of some types of attenuator can be permanently decreased after laser damage, which is the route by which Eve raises the mean photon number and with it her success rate [Zhang2022,Pang2020].

A-0066 Injection-Locking Attack (ILA)

Scoped deliberately to one rung of the effect ladder. The destructive rungs announce themselves, since a detector at complete insensitivity stops counting and a satellite in complete failure stops responding [Krelina2023]. The rung worth monitoring for is the intermediate one, where high-power light leaves the avalanche photodiode permanently blinded [Krelina2023]. The detector then stops counting single photons but can still be controlled with bright light [Bugge2014]. That is exactly what this control assesses components for, and it is the same rung that gives this technique its degradation attack type.

A-0037 Non-Kinetic Physical Attack

Continuous device functionality monitoring answers one specific case in this family and not its main one, and the scope matters because overstating it would credit the control with stopping an outage it cannot stop. The main case needs no monitor: a cut span, a melted detector and a module in an error state all announce themselves. What monitoring buys is the case Bugge2014 names, where the threat actor "could for instance wait for a power outage, and perform the damage when the system is unpowered" [Bugge2014], so a system can come back up damaged and be trusted anyway unless it is re-characterised before service resumes. Monitoring characteristics during operation rather than only at installation is that paper's own recommendation. That is one case out of several, and the control's main benefit, catching characterisation drift on a device that keeps running, belongs to the A-0058 branch rather than to this family.

A-0048 Destruction

Continuous functionality monitoring of the isolation itself, as opposed to monitoring the field; a detection control rather than a preventive one. BSI's general countermeasure C3 asks for this monitoring against laser damage [BSI2023]; the same check applies to an isolator degraded by a field.

A-0053 External Magnetic Field Attack on Optical Isolators and Circulators

Every quantitative defence claim for this technique is an isolation budget in dB, and that budget silently assumes the isolator still meets its specification. [Ponosova2025] shows it may not: out-of-band pulsed light permanently degrades an isolator's reverse isolation while forward transmission is less affected, so the link may keep running. [Huang2019] independently notes the isolator's isolation is temperature-dependent and can be reduced by heating it. Periodically re-verifying that protective components still perform to specification is therefore the control that keeps the rest of the budget honest.

A-0063 Laser Seeding Attack (LSA)
Countermeasure → Security Layers 1
Description Category Impact Type

System Control and Orchestration. Unlike the optical controls in this family, this one periodically re-checks whether components still match their modelled behaviour, so it lives in the control plane rather than in the light path. That is exactly the mechanism Makarov2016 says deployed systems lack, a way to check all possible deviations in device characteristics from the modelled values [Makarov2016].

L4 — System Control & Orchestration Primary Defence
See Also
CM-0008 Employment of Optical Isolation
CM-0011 Watchdog Detector
CM-0013 Employment of Optical Filters
CM-0014 Full Device Imperfections Incorporation in Scientific Security Proof
CM-0015 Active Phase Randomisation