Enabling Light-Injection Attacks by Application of External Magnetic Felds
Enabling light-injection attacks through the application of external magnetic fields represents a method where manipulation of the optical components, such as an optical isolator or circulator, can lead to abnormal functionality and allow subsequent THA attacks by injecting a pulse.
Literature
[BSI2023] | BSI. "Implementation Attacks against QKD Systems". (2023) https://www.bsi.bund.de/SharedDocs/Downloads/EN/BSI/Publications/Studies/QKD-Systems/QKD-Systems.pdf. |
[Tan2022] | H. Tan, W. Zhang, L. Zhang, W. Li, S. Liao, and F. Xu. "External magnetic efect for the security of practical quantum key distribution" In: Quantum Sci. Technol. 7 045008. (2022) 10.1088/2058-9565/ac7d07. |
Technique → Countermeasures
List of countermeasures applicable to this technique.
Items: 2
Description | Countermeasure |
---|---|
External magnetic field monitoring. |
|
Optimal quantum communication devices design. |